Columns, Reagents and Post-column derivatization systems (interfaces with all major brands of HPLC) Suppliers

List / Directory of Pharmaceutical Companies / Suppliers and useful resource.
Number One for Equipment, News, Events, Projects and Suppliers
projects products & services home suppliers industry news
Click here to join us
 

Pickering Laboratories Inc - Analytical Equipment and Chemical Suppliers - Products/Services  Pickering Laboratories Inc - Analytical Equipment and Chemical Suppliers - Products/Services

Pharmaceutical Products & Services Pharmaceutical Products & Services

 

Products & Services

Pickering Laboratories manufactures complete post-column systems, columns, Chromatographic Grade™ chemicals and reagents for EPA, FDA and AOAC methods.

The model PCX5200 is a post-column derivatization system easily configurable to detect a wide range of compounds with high sensitivity and very specifically. Designed to interface with all major brands of HPLC, the PCX5200 is available with a programming interface with HPLC software for programming operations and monitoring.

With the PCX5200 it is easy to convert between applications, whether using single or two-step post-column derivatization, by the addition of one or more Applications Kits. These Kits include columns, Pickering’s Chromatographic Grade™ eluants and post-column reagents. The PCX5200 can be configured with several different reactors and flow-conditioner panels to support a variety of methodologies including custom designs.

Modular design facilitates re-configuration or upgrades by the user for a range of HPLC post-column applications. Modular design facilitates re-configuration or upgrades by the user for a range of HPLC post-column applications.
Front-removable Gauge/Flow Conditioner panels for easy substitution of panels and access to internal components for service or substitutions. Front-removable Gauge/Flow Conditioner panels for easy substitution of panels and access to internal components for service or substitutions.
Inge S.p.A Address Built-in Column Heater accessible from front.
Microprocessor Control: Five user-adjustable preset temperatures for different applications; Flash ROM for external control or monitoring (requires user-written programming). Microprocessor Control: Five user-adjustable preset temperatures for different applications; Flash ROM for external control or monitoring (requires user-written programming).
Low-pulsation precision metering pumps for reproducibility; piston seal wash to extend seal life. Low-pulsation precision metering pumps for reproducibility; piston seal wash to extend seal life.
Reagent pulse-damping network for smooth baseline. Reagent pulse-damping network for smooth baseline.
Reactor with heavy-wall PTFE capillary allows operation pressure up to 35 bar (500 psi); standard and custom volumes available. Reactor with heavy-wall PTFE capillary allows operation pressure up to 35 bar (500 psi); standard and custom volumes available.
Reagent reservoirs pressurized by inert gas to extend working life of oxygen-sensitive reagents and enhanced pump performance. Reagent reservoirs pressurized by inert gas to extend working life of oxygen-sensitive reagents and enhanced pump performance.
Column pressure interlock permits unattended operation with controlled shutdown; prevents reagent back-flow into column. Column pressure interlock permits unattended operation with controlled shutdown; prevents reagent back-flow into column.
Non-metallic flow-path option permits use of corrosive reagents such as Sulfuric Acid in Methanol. Non-metallic flow-path option permits use of corrosive reagents such as Sulfuric Acid in Methanol.

Our chemistry department has delivered and continues to develop Custom Applications for pharmaceutical QC and trace analysis. Efforts in this regard often entail purification of key ingredients. Regulatory agencies also benefit by our ability to improve current methods and assist in crafting new methods.

The quality and consistency of the PCX5200 system, columns and reagents and technical support is so good that Pickering Laboratories guarantees the chromatogram. The components of the Pickering Laboratory guaranteed chromatogram include; the PCX5200 post-column system, chemically specific columns, Chromatographic Grade™ chemistry and thorough application manuals and technical support provided by chemists.

 

The model PCX5200 is a post-column derivatization system easily configurable to detect a wide range of compounds with high sensitivity and very specifically. Designed to interface with all major brands of HPLC.

Sub Menu  

Pickering Laboratories Inc - About Us About Us
Pickering Laboratories  Inc - Contact Us Contact Us
Pickering Laboratories Inc - Visit our Website Visit Our Website

Address

Pickering Laboratories  Inc Address Pickering Laboratories Inc
  1280 Space Park Way,
Mountain View,
  CA 940043-1434,
  USA
Tel. +1 650 694 6700
Fax +1 650 968 0749


  
 
 
about us
 contact us events join our directory resources site map
Phone No : +44 208 445 5303         Fax No : +44 845 280 3373  
E-mail : info@pharmaceutical-industry.info

Privacy Statement    Legal    Copyright© 2002 Pharmaceutical-Industry.Info. All rights reserved.